diff options
author | Alex Auvolat <alex@adnab.me> | 2022-03-28 16:20:15 +0200 |
---|---|---|
committer | Alex Auvolat <alex@adnab.me> | 2022-03-28 16:26:04 +0200 |
commit | 0091002ef2fe5761cc6c325490be2f01b2090600 (patch) | |
tree | c99498ac7050d2267513336d4013f270656d874b /doc/book/reference-manual | |
parent | 8f9cf3a5d10dafc28b717e89c8c5944c2de1b2f7 (diff) | |
download | garage-0091002ef2fe5761cc6c325490be2f01b2090600.tar.gz garage-0091002ef2fe5761cc6c325490be2f01b2090600.zip |
New replication modes and their documentationfeature/documentation
Diffstat (limited to 'doc/book/reference-manual')
-rw-r--r-- | doc/book/reference-manual/configuration.md | 87 |
1 files changed, 70 insertions, 17 deletions
diff --git a/doc/book/reference-manual/configuration.md b/doc/book/reference-manual/configuration.md index 7a3f37b3..bb04650c 100644 --- a/doc/book/reference-manual/configuration.md +++ b/doc/book/reference-manual/configuration.md @@ -48,7 +48,6 @@ root_domain = ".web.garage" [admin] api_bind_addr = "0.0.0.0:3903" trace_sink = "http://localhost:4317" - ``` The following gives details about each available configuration option. @@ -89,20 +88,47 @@ might use more storage space that is optimally possible. Garage supports the following replication modes: -- `none` or `1`: data stored on Garage is stored on a single node. There is no redundancy, - and data will be unavailable as soon as one node fails or its network is disconnected. - Do not use this for anything else than test deployments. - -- `2`: data stored on Garage will be stored on two different nodes, if possible in different - zones. Garage tolerates one node failure before losing data. Data should be available - read-only when one node is down, but write operations will fail. - Use this only if you really have to. - -- `3`: data stored on Garage will be stored on three different nodes, if possible each in - a different zones. - Garage tolerates two node failure before losing data. Data should be available - read-only when two nodes are down, and writes should be possible if only a single node - is down. +- `none` or `1`: data stored on Garage is stored on a single node. There is no + redundancy, and data will be unavailable as soon as one node fails or its + network is disconnected. Do not use this for anything else than test + deployments. + +- `2`: data stored on Garage will be stored on two different nodes, if possible + in different zones. Garage tolerates one node failure, or several nodes + failing but all in a single zone (in a deployment with at least two zones), + before losing data. Data remains available in read-only mode when one node is + down, but write operations will fail. + + - `2-dangerous`: a variant of mode `2`, where written objects are written to + the second replica asynchronously. This means that Garage will return `200 + OK` to a PutObject request before the second copy is fully written (or even + before it even starts being written). This means that data can more easily + be lost if the node crashes before a second copy can be completed. This + also means that written objects might not be visible immediately in read + operations. In other words, this mode severely breaks the consistency and + durability guarantees of standard Garage cluster operation. Benefits of + this mode: you can still write to your cluster when one node is + unavailable. + +- `3`: data stored on Garage will be stored on three different nodes, if + possible each in a different zones. Garage tolerates two node failure, or + several node failures but in no more than two zones (in a deployment with at + least three zones), before losing data. As long as only a single node fails, + or node failures are only in a single zone, reading and writing data to + Garage can continue normally. + + - `3-degraded`: a variant of replication mode `3`, that lowers the read + quorum to `1`, to allow you to read data from your cluster when several + nodes (or nodes in several zones) are unavailable. In this mode, Garage + does not provide read-after-write consistency anymore. The write quorum is + still 2, ensuring that data successfully written to Garage is stored on at + least two nodes. + + - `3-dangerous`: a variant of replication mode `3` that lowers both the read + and write quorums to `1`, to allow you to both read and write to your + cluster when several nodes (or nodes in several zones) are unavailable. It + is the least consistent mode of operation proposed by Garage, and also one + that should probably never be used. Note that in modes `2` and `3`, if at least the same number of zones are available, an arbitrary number of failures in @@ -111,8 +137,35 @@ any given zone is tolerated as copies of data will be spread over several zones. **Make sure `replication_mode` is the same in the configuration files of all nodes. Never run a Garage cluster where that is not the case.** -Changing the `replication_mode` of a cluster might work (make sure to shut down all nodes -and changing it everywhere at the time), but is not officially supported. +The quorums associated with each replication mode are described below: + +| `replication_mode` | Number of replicas | Write quorum | Read quorum | Read-after-write consistency? | +| ------------------ | ------------------ | ------------ | ----------- | ----------------------------- | +| `none` or `1` | 1 | 1 | 1 | yes | +| `2` | 2 | 2 | 1 | yes | +| `2-dangerous` | 2 | 1 | 1 | NO | +| `3` | 3 | 2 | 2 | yes | +| `3-degraded` | 3 | 2 | 1 | NO | +| `3-dangerous` | 3 | 1 | 1 | NO | + +Changing the `replication_mode` between modes with the same number of replicas +(e.g. from `3` to `3-degraded`, or from `2-dangerous` to `2`), can be done easily by +just changing the `replication_mode` parameter in your config files and restarting all your +Garage nodes. + +It is also technically possible to change the replication mode to a mode with a +different numbers of replicas, although it's a dangerous operation that is not +officially supported. This requires you to delete the existing cluster layout +and create a new layout from scratch, meaning that a full rebalancing of your +cluster's data will be needed. To do it, shut down your cluster entirely, +delete the `custer_layout` files in the meta directories of all your nodes, +update all your configuration files with the new `replication_mode` parameter, +restart your cluster, and then create a new layout with all the nodes you want +to keep. Rebalancing data will take some time, and data might temporarily +appear unavailable to your users. It is recommended to shut down public access +to the cluster while rebalancing is in progress. In theory, no data should be +lost as rebalancing is a routine operation for Garage, although we cannot +guarantee you that everything will go right in such an extreme scenario. ### `compression_level` |